Home >Products> Physiology | Pharmacology | Neurology >Electrophysiology> 博坊在线
Physiology | Pharmacology | Neurology: Electrophysiology Microtome Animal Experimental Equipment Animal Cages
博坊在线
Place of Origin:
博坊在线
Brand:
博坊在线
Model:
博坊在线
Supplier:
博坊在线
Price:
Hits:
3900
Updated:
12/8/2023
  • Product Detail
  • Company Profile
    Medlab—U/4C501 博坊在线

    Newly added and main improving points
    ①Adopt high resistance(10E12Ω , 3pF), low nose. low drift 8i high function’s amplifier fuse to be ready, so it has such advantages as strong anti—interference, good linear degree and high measuring accuracy.
    ②Adopt USB 2.0 structure to transmit data, so its velocity is more high, and guarantees data’s continuous collection.

    ③Add 9 stage Besil low-pass wave filter newly, bi close to ideal condition
    ④Add 50Hz hardware wave frame circuit and datum tracing circuit newly
    ⑤Enlarge inputting electrical level’s scope to ±1.2v ,it’s very important to this condition that there is higher polarization voltage though the signal is very weak.
    ⑥Magnifying times is from 1,2,5,to 5000 so it can adapt to many kinds of signals.
    ⑦When outputting voltage is to 100v outputting current is to 100ma from electrical stimulator, it will separate light from electricity and be safe.

    Amplifier technical index
    No Item Parameter''s demand
    1 Channel''s number, Four—channel amplifier has the same function adjustable parameter control and part technology
    2 Inputting mode. Tow sends balance inputs differentially
    3 Inputting resistance 100M
    4 Gain transverter 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000 ,10000, 20000, 50000
    5 Gain accuracy 0.5% (FS) ( an hour''s preliminary heating later)
    6 Gain accuracy 0.05%(FS) (an hour''s preliminary heating later)
    7 Gain stability 0.1 percent of full degree
    8 Linear degree <1%
    9 Distortion factor DC—30KHZC+0.5db—3db
    10 Nose <3 MVRMS( Inputting short circuit, at maximum gain 30k wide band, it will convert to in putting end) <2uvRMS(Inputting short circuit, at maximum gain 30k wide band, it will convert to outputting end )
    11 Common mode''s restrain >100db
    12 Time drift <3MV/H (Inputting short circuit, at maximum gain, it will convert to inputting end)
    13 Temperature drift <3mv/h(Inputting short circuit, at maximum gain, it will convert to outputting end )
    14 Upper limit frequency When voltage is DC—30kHz, its transverter is 10, you also can input upper limit frequency freely
    15 Wave filter character 9-stage Besil low-pass wave filter
    16 Time constant DC 5s,2s,1s,0.2s,0.002s, 0.001s, 0.005s, adds up to 9 transverters altogether, you can switch freely
    17 50 Hz wave frame Have but attenuate 32 db
    18 Datum tracing Have and overcome datum drift
    19 Monitor function Monitor four channels freely
    20 Note drop function Four channel all can note including drops, drop velocity


    Stimulator parameter

    No
    Item
    Parameter''s demand
    1
    Range
    0-100v''s distance 13/mv
    2
    Outputting current
    100mm
    3

    Wave width

    0.1-600ms, program adjustable distance is 0.1ms
    4
    Delay
    1-250ms, program adjustable distance is 0.1ms
    5
    Operating mode
    Alone stimulation, crossing stimulation main period stimulation, automatic intermission stimulation, automatic range adjusting stimulation automatic wave width adjusting stimulation, automatic frequency adjusting stimulation
    6
    Stimulation pulse value
    Free
    7
    Stimulation series length
    free
    8
    Stimulation series intermission
    Free
    Operating table
    1
    Backing system
    Win2000/Winxp
    2
    Data transmission
    Full velocity USB structure.
    Established in 2004,headquarter in Anhui, branch in Beijing, Shanghai we are a professional manufacturer, Serving the basic medical and biological research field for animal experiment equipment development, production, sales and service as a professional technical enterprise
Request Infomation
Request Infomation: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Infomation

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Infomation:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.