Technical Parameter
-Over-temperature protection can be set, and the automatic power-off system will be activated when the temperature is reached!
-Liwen integrated light source controller can be used for various light sources such as mercury lamp, xenon lamp.
-Power adjustment range of mercury lamp: 100~1000W adjustable.
-Power adjustment range of xenon lamp: 100~1000W adjustable.
-Refrigeration capacity of cooling water circulation device: >1000W
-The cooling water circulation device is equipped with casters and bottom drain valve, temperature range 5~35℃, volume: 10L
-eight tube magnetic stirrer - optional test tube 5ml, 10ml, 15ml, 20ml, 30ml, 50ml
-Specifications of quartz test tubes: 30ml, 50ml (or customized).
-Can process 8 samples at the same time (or customized).
-The eight-position magnetic stirring device can simultaneously adjust the stirring speed of 8 samples
1. Reaction camera obscura
-Dark chamber of size 500mm × 780mm × 450mm, weighs about 20kg.
-Inside the black box in order to reduce light reflection.
-2 side with holes to connect the cooling water pipe
-On the back has fan for ventilation.
2. The Light Source Controller
--Intelligent touch controller, stable and real-time monitoring of light intensity, making experiments more accurate.
--The power range can be set from 100W to 1000W.
--Response time can be set as needed.
--Size:32*40*25cm(L*W*H)
3. Mercury and mercury electric controller
Dimensions and photoelectric parameters of high-pressure mercury lamp:
Power(W)
|
Starting current A
|
Working
Current A
|
Working
Voltage V
|
Effective length of arc MM
|
Wiring
|
1000
|
12
|
10
|
220±20
|
170±10
|
Single-ended leads
|
4. Xenon lamp and xenon lamp electrical controller
Xenon lamp optical parameters are as follows:
Power (W)
|
Starting
Current (A)
|
Operating Current(A)
|
Operating Voltage(V)
|
Effective arc length(MM)
|
Wiring
|
500
|
8.3
|
18±3
|
50
|
220±20
|
Single-ended leads
|
1000
|
12.4
|
30±3
|
60
|
5. All quartz glass light protection or improvement of the cold trap
Light source protection cold trapLamp placed in position
6. Special Reaction, Photochemical Reactor for Small sample, can be processed 8 different samples
special reactor is a new type of reactor, the product promotion in the major university laboratory trials with successful results, praised by users.
Mixing capacity
|
Stirring speed
|
50ml
|
Stepless speed 0 ~ 1600
|
Mixing method
|
Working voltage
|
Strong magnetic
|
220V 50Hz
|
Accessories
Series
|
Name
|
Qty
|
Configure as required
|
1
|
Reaction camera obscura
|
1 Set
|
Standard
|
2
|
Intelligent touch controller
|
1 Set
|
Standard
|
3
|
Quartz cold trap
|
1 Pc
|
Standard
|
4
|
Mercury lamp 1000W
|
1 Pc
|
Standard
|
5
|
Xenon lamp 1000W
|
1 pc
|
Standard
|
6
|
Metal halide lamp 1000W
|
1 pc
|
Standard
|
7
|
8-Magnetic stirrer
|
1Set
|
√ Optional
|
8
|
16pcs Jacketed Test tube(30ml 50ml)
|
√ Optional
|
9
|
Magnetic stirrer 1000W
|
1 Set
|
√ Optional
|
10
|
Sample reaction bottle(250ml or 500ml or 1000ml or made to order)
|
1 pc
|
√ Optional
|
11
|
High temperature circulator (Heating up to 80 degree celsius)
|
1 Set
|
√ Optional
|
12
|
Filter above 400nm pass through and cut off below
|
8 pc
|
√ Optional
|
13
|
Filter below 400nm pass through and cut off above
|
8 pc
|
√ Optional
|
14
|
Moving the cart
|
1 Set
|
Standard
|
15
|
Cooling water circulation device (Cool down the light source)
|
1 Set
|
Standard
|
16
|
Protective goggles
|
2 Pcs
|
Standard
|
17
|
Connected fixture and silicone tube
|
Some
|
Standard
|
Can also be customized according to requirements
|
1x2arena.net